Local Storage seems to be disabled in your browser.
For the best experience on our site, be sure to turn on Local Storage in your browser.

Schneider GZ1E21, Motor Circuit Breaker, Easy TeSys Power, GZ1E, AC-3, 3 Pole, 17~23A, Thermal Magnetic Trip
Schneider GZ1E21, Motor Circuit Breaker, Easy TeSys Power, GZ1E, AC-3, 3 Pole, 17~23A, Thermal Magnetic Trip Schneider GZ1E21, Motor Circuit Breaker, Easy TeSys Power, GZ1E, AC-3, 3 Pole, 17~23A, Thermal Magnetic Trip Schneider GZ1E21, Motor Circuit Breaker, Easy TeSys Power, GZ1E, AC-3, 3 Pole, 17~23A, Thermal Magnetic Trip

Schneider GZ1E21, Motor Circuit Breaker, Easy TeSys Power, GZ1E, AC-3, 3 Pole, 17~23A, Thermal Magnetic Trip

In stock
SKU
GZ1E21
Special Price ₹4,425.10 Regular Price ₹11,645.00
(18% GST Extra)
Add to Wish List
  • 3 pole thermal-magnetic circuit breakers designed for motor control and protection, conforming to IEC 60947-2 and IEC 60947-4-1 standards.
  • Thermal trip setting range: 17~23A with thermo-magnetic trip unit.
  • Provides IP41 protection in GV2 MC01 enclosure and IP55 protection in GV2 MC02 enclosure.
  • Ensures reliability with 0.1 Mcycles electrical/mechanical durability and screw clamp terminal connections.
  • Globally available, multi-standard certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHS/REACH).
Schneider GZ1E21, Motor Circuit Breaker, Easy TeSys Power, GZ1E, AC-3, 3 Pole, 17~23A, Thermal Magnetic Trip is available to buy in increments of 1
Check Delivery Options at your Area

FREE SHIPPING

Free Shipping by Surface Only*

SECURE PAYMENT

100% Secure Payment

Main
Range Easy TeSys
Range of product Easy TeSys Power
Product or component type Circuit breaker
Device short name GZ1E
Device application Motor
Trip unit technology Thermal-magnetic
Suitability for isolation Yes conforming to IEC 60947-1 appendix 7.1.6
Colour Grey (RAL 7011)
Complementary
Poles description 3P
Network type AC
Utilisation category AC-3
Network frequency 50/60 Hz conforming to IEC 60947-2
Mounting mode By clips / By screws
Mounting support Rail
Mounting position Any position
Motor power kW 5.5 kW at 230 V AC 50/60 Hz
9 kW at 400 V AC 50/60 Hz
11 kW at 440 V AC 50/60 Hz
11 kW at 500 V AC 50/60 Hz
18.5 kW at 690 V AC 50/60 Hz
Breaking capacity Icu: 2 kA at 690 V AC 50/60 Hz
Icu: 10 kA at 400/415 V AC 50/60 Hz
Icu: 30 kA at 230/240 V AC 50/60 Hz
Icu: 5 kA at 440 V AC 50/60 Hz
Icu: 3 kA at 500 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz
75 % at 690 V AC 50/60 Hz
50 % at 440 V AC 50/60 Hz
75 % at 500 V AC 50/60 Hz
40 % at 400/415 V AC 50/60 Hz
Control type Push-button
Thermal protection adjustment range 17…23 A
Magnetic tripping current 327 A
[Ue] rated operational voltage 690 V AC 50/60 Hz
[Ui] rated insulation voltage 690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 6 kV
Power dissipation 2.5 W (per pole)
Mechanical durability 100000 cycles
Electrical durability 100000 cycles for AC-3
Maximum operating rate 25 cyc/h
Connections - terminals Screw clamp terminals 2 1…6 mm² - solid
Screw clamp terminals 2 1.5…6 mm² - flexible without cable end
Screw clamp terminals 2 1…4 mm² - flexible with cable end
Height 89 mm
Width 44.5 mm
Depth 78 mm

No specifications available for this product.

Write Your Own Review
You're reviewing:Schneider GZ1E21, Motor Circuit Breaker, Easy TeSys Power, GZ1E, AC-3, 3 Pole, 17~23A, Thermal Magnetic Trip
Your Rating