Schneider LC1D32M7, TeSys D contactor - 3P, 440V, 32 A, 220V AC coil
Schneider LC1D32M7, TeSys D contactor - 3P, 440V, 32 A, 220V AC coil Schneider LC1D32M7, TeSys D contactor - 3P, 440V, 32 A, 220V AC coil Schneider LC1D32M7, TeSys D contactor - 3P, 440V, 32 A, 220V AC coil Schneider LC1D32M7, TeSys D contactor - 3P, 440V, 32 A, 220V AC coil

Schneider LC1D32M7, TeSys D contactor - 3P, 440V, 32 A, 220V AC coil

In stock
SKU
LC1D32M7
Special Price ₹4,086.00 Regular Price ₹10,215.00
(18% GST Extra)
Add to Wish List
  • New modern look & feel of all machines
  • Easier to install and operate with multi-standard screws
  • 3 poles
  • Motor control applications up to 32A/690V AC-3/3e (15kW@400V)
  • Provides a 220V 50/60Hz AC coil
  • 1NO+1NC built-in auxiliary contacts (NC mirror certified)
  • Operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability
  • Compact (45mm width), DIN-rail mounting or screw fixing
Schneider LC1D32M7, TeSys D contactor - 3P, 440V, 32 A, 220V AC coil is available to buy in increments of 1
Check Delivery Options at your Area

FREE SHIPPING

Free Shipping by Surface Only*

SECURE PAYMENT

100% Secure Payment

TeSys Deca LC1D – 32 A / 50 A – 220 V AC 50/60 Hz
Main
Range of productTeSys Deca
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load
Motor control
Utilisation categoryAC-4
AC-1
AC-3
AC-3e
Poles description3P
[Ue] rated operational voltagePower circuit: ≤ 690 V AC 25…400 Hz
Power circuit: ≤ 300 V DC
[Ie] rated operational current 32 A (<60 °C) at ≤ 440 V AC AC-3 for power circuit
50 A (<60 °C) at ≤ 440 V AC AC-1 for power circuit
32 A (<60 °C) at ≤ 440 V AC AC-3e for power circuit
[Uc] control circuit voltage220 V AC 50/60 Hz
Complementary
Motor power kW 7.5 kW at 220…230 V AC 50/60 Hz (AC-3)
15 kW at 380…400 V AC 50/60 Hz (AC-3)
15 kW at 415…440 V AC 50/60 Hz (AC-3)
18.5 kW at 500 V AC 50/60 Hz (AC-3)
18.5 kW at 660…690 V AC 50/60 Hz (AC-3)
7.5 kW at 400 V AC 50/60 Hz (AC-4)
7.5 kW at 220…230 V AC 50/60 Hz (AC-3e)
15 kW at 380…400 V AC 50/60 Hz (AC-3e)
15 kW at 415…440 V AC 50/60 Hz (AC-3e)
18.5 kW at 500 V AC 50/60 Hz (AC-3e)
18.5 kW at 660…690 V AC 50/60 Hz (AC-3e)
Motor power hp 2 hp at 115 V AC 50/60 Hz for 1-phase motors
5 hp at 230/240 V AC 50/60 Hz for 1-phase motors
10 hp at 200/208 V AC 50/60 Hz for 3-phase motors
10 hp at 230/240 V AC 50/60 Hz for 3-phase motors
20 hp at 460/480 V AC 50/60 Hz for 3-phase motors
25 hp at 575/600 V AC 50/60 Hz for 3-phase motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit
50 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for signalling circuit (IEC 60947-5-1)
250 A DC for signalling circuit (IEC 60947-5-1)
550 A at 440 V for power circuit (IEC 60947)
Rated breaking capacity550 A at 440 V for power circuit (IEC 60947)
[Icw] rated short-time withstand current 260 A 40 °C – 10 s for power circuit
430 A 40 °C – 1 s for power circuit
60 A 40 °C – 10 min for power circuit
138 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit (IEC 60947-5-1)
63 A gG at ≤ 690 V coordination type 1 for power circuit
63 A gG at ≤ 690 V coordination type 2 for power circuit
Average impedance2 mΩ – Ith 50 A 50 Hz for power circuit
Power dissipation per pole5 W AC-1
2 W AC-3
2 W AC-3e
[Ui] rated insulation voltage Power circuit: 690 V (IEC 60947-4-1)
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V (IEC 60947-1)
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV (IEC 60947)
Safety reliability level B10d = 1 369 863 cycles (nominal load) EN/ISO 13849-1
B10d = 20 000 000 cycles (mechanical load) EN/ISO 13849-1
Mechanical durability15 Mcycles
Electrical durability 1.65 Mcycles 32 A AC-3 at Ue ≤ 440 V
1.4 Mcycles 50 A AC-1 at Ue ≤ 440 V
1.65 Mcycles 32 A AC-3e at Ue ≤ 440 V
Control circuit typeAC at 50/60 Hz standard
Coil technologyWithout built-in suppressor module
Control circuit voltage limits 0.3…0.6 Uc (–40…70 °C): drop-out AC 50/60 Hz
0.8…1.1 Uc (–40…60 °C): operational AC 50 Hz
0.85…1.1 Uc (–40…60 °C): operational AC 60 Hz
1…1.1 Uc (60…70 °C): operational AC 50/60 Hz
Inrush power in VA70 VA 60 Hz cos φ 0.75 (20 °C)
70 VA 50 Hz cos φ 0.75 (20 °C)
Hold-in power consumption in VA7.5 VA 60 Hz cos φ 0.3 (20 °C)
7 VA 50 Hz cos φ 0.3 (20 °C)
Heat dissipation2…3 W at 50/60 Hz
Operating time12…22 ms closing
4…19 ms opening
Maximum operating rate3600 cyc/h at 60 °C
Connections – terminals Control circuit: screw clamp 1 1…4 mm² – flexible without cable end
Control circuit: screw clamp 2 1…4 mm² – flexible without cable end
Control circuit: screw clamp 1 1…4 mm² – flexible with cable end
Control circuit: screw clamp 2 1…2.5 mm² – flexible with cable end
Control circuit: screw clamp 1 1…4 mm² – solid without cable end
Control circuit: screw clamp 2 1…4 mm² – solid without cable end
Power circuit: screw clamp 1 2.5…10 mm² – flexible without cable end
Power circuit: screw clamp 2 2.5…10 mm² – flexible without cable end
Power circuit: screw clamp 1 1…10 mm² – flexible with cable end
Power circuit: screw clamp 2 1.5…6 mm² – flexible with cable end
Power circuit: screw clamp 1 1.5…10 mm² – solid without cable end
Power circuit: screw clamp 2 2.5…10 mm² – solid without cable end
Tightening torque Control circuit: 1.7 N·m – flat Ø 6 mm / Philips No 2 / pozidriv No 2
Power circuit: 2.5 N·m – flat Ø 6 mm / Philips No 2 / pozidriv No 2
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC (IEC 60947-5-1)
type mirror contact 1 NC (IEC 60947-4-1)
Signalling circuit frequency25…400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MΩ for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting supportScrew
DIN Rail

No specifications available for this product.

Write Your Own Review
You're reviewing:Schneider LC1D32M7, TeSys D contactor - 3P, 440V, 32 A, 220V AC coil
Your Rating