Schneider LC1E160M5, Easy TeSys contactor 3P, 440V, 160A, 220V AC coil
In stock
SKU
LC1E160M5
Special Price
₹15,030.60
Regular Price
₹38,540.00
Check Delivery Options at your Area


FREE SHIPPING
Free Shipping by Surface Only*


SECURE PAYMENT
100% Secure Payment
| Main | |
|---|---|
| Range | Easy TeSys |
| Range of product | Easy TeSys Control |
| Product or component type | Contactor |
| Device short name | LC1E |
| Contactor application | Motor control Resistive load |
| Utilisation category | AC-3 AC-3e AC-1 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: ≤ 690 V AC 50/60 Hz |
| [Ie] rated operational current |
160 A (at <55 °C) at ≤ 440 V AC AC-3 for power circuit 100 A (at <55 °C) at ≤ 440 V AC AC-3e for power circuit 200 A (at <40 °C) at ≤ 440 V AC AC-1 for power circuit |
| [Uc] control circuit voltage | 220 V AC 50 Hz |
| Complementary | |
| Motor power kW |
45 kW at 220/230 V AC 50/60 Hz 75 kW at 380/400 V AC 80 kW at 415/440 V AC 90 kW at 500 V AC 100 kW at 660/690 V AC 100 kW at 660...690 V |
| Pole contact composition | 3 NO |
| [Ith] conventional free air thermal current | 200 A (at 40 °C) for power circuit |
| Irms rated making capacity | 1600 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
| Rated breaking capacity | 1280 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 1400 A 40 °C - 10 s for power circuit |
| Associated fuse rating |
10 A gG at ≤ 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 315 A gG at ≤ 690 V coordination type 1 for power circuit |
| Average impedance | 0.6 mOhm - Ith 200 A 50 Hz for power circuit |
| Power dissipation per pole | 24 W AC-1 15 W AC-3 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 8 kV coil not connected to the power circuit conforming to IEC 60947 |
| Mechanical durability | 4,000,000 cycles |
| Electrical durability | 800,000 cycles AC-3 250,000 cycles AC-1 |
| Control circuit type | AC at 50 Hz |
| Control circuit voltage limits |
0.85...1.1 Uc (-5…55 °C): operational 50 Hz 0.35...0.55 Uc (-5…55 °C): drop-out 50 Hz |
| Inrush power in VA |
300 VA 50 Hz cos φ 0.9 (at 20 °C) 300 VA 60 Hz cos φ 0.9 (at 20 °C) |
| Hold-in power consumption in VA |
22 VA 50 Hz cos φ 0.9 (at 20 °C) 22 VA 60 Hz cos φ 0.9 (at 20 °C) |
| Heat dissipation | 3…8 W for control circuit |
| Operating time | 20...50 ms on closing 6...20 ms on opening |
| Maximum operating rate | 1200 cyc/h 55 °C |
| Connections - terminals |
Power circuit: screw clamp terminals 1 10…120 mm² - flexible without cable end Power circuit: screw clamp terminals 1 10…120 mm² - flexible with cable end Power circuit: screw clamp terminals 1 10…120 mm² - solid without cable end Control circuit: screw clamp terminals 1 1…2.5 mm² - flexible without cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - flexible without cable end Control circuit: screw clamp terminals 1 1…2.5 mm² - flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - flexible with cable end Control circuit: screw clamp terminals 1 1…2.5 mm² - solid without cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - solid without cable end Power circuit: screw clamp terminals 2 10…120 mm² - solid without cable end |
| Tightening torque | Power circuit: 12 N·m Control circuit: 1.2 N·m |
| Auxiliary contact composition | 1 NO + 1 NC |
| Minimum switching voltage | 17 V for control circuit |
| Minimum switching current | 5 mA for control circuit |
| Insulation resistance | > 10 MOhm for control circuit |
| Non-overlap time |
1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact |
| Mounting support | Screw DIN rail |
No specifications available for this product.