Schneider LC1E160M5, Easy TeSys contactor 3P, 440V, 160A, 220V AC coil
In stock
SKU
LC1E160M5
Special Price
₹15,030.60
Regular Price
₹38,540.00
Check Delivery Options at your Area


FREE SHIPPING
Free Shipping by Surface Only*


SECURE PAYMENT
100% Secure Payment
- Range: Easy TeSys
- Range of product: Easy TeSys Control
- Product or component type: Contactor
- Device short name: LC1E
- Contactor application:
- Motor control
- Resistive load
- Utilisation category:
- AC-3
- AC-3e
- AC-1
- Poles description: 3P
- [Ue] rated operational voltage: Power circuit: <= 690 V AC 50/60 Hz
- [Ie] rated operational current:
- 160 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
- 100 A (at <55 °C) at <= 440 V AC AC-3e for power circuit
- 200 A (at <40 °C) at <= 440 V AC AC-1 for power circuit
- [Uc] control circuit voltage: 220 V AC 50 Hz
- Motor power kW:
- 45 kW at 220/230 V AC 50/60 Hz
- 75 kW at 380/400 V AC
- 80 kW at 415/440 V AC
- 90 kW at 500 V AC
- 100 kW at 660/690 V AC
- 100 kW at 660...690 V
- Pole contact composition: 3 NO
- [Ith] conventional free air thermal current: 200 A (at 40 °C) for power circuit
- Irms rated making capacity: 1600 A at 440 V AC for power circuit conforming to IEC 60947-4-1
- Rated breaking capacity: 1280 A at 440 V for power circuit conforming to IEC 60947
- [Icw] rated short-time withstand current: 1400 A 40 °C - 10 s for power circuit
- Associated fuse rating:
- 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1
- 315 A gG at <= 690 V coordination type 1 for power circuit
- Average impedance: 0.6 mOhm - Ith 200 A 50 Hz for power circuit
- Power dissipation per pole:
- 24 W AC-1
- 15 W AC-3
- [Ui] rated insulation voltage: 690 V conforming to IEC 60947-4-1
- Overvoltage category: III
- Pollution degree: 3
- [Uimp] rated impulse withstand voltage: 8 kV coil not connected to the power circuit conforming to IEC 60947
- Mechanical durability: 4000000 cycles
- Electrical durability:
- 800000 cycles AC-3
- 250000 cycles AC-1
- Control circuit type: AC at 50 Hz
- Control circuit voltage limits:
- 0.85...1.1 Uc (-5…55 °C): operational 50 Hz
- 0.35...0.55 Uc (-5…55 °C): drop-out 50 Hz
- Inrush power in VA:
- 300 VA 50 Hz cos phi 0.9 (at 20 °C)
- 300 VA 60 Hz cos phi 0.9 (at 20 °C)
- Hold-in power consumption in VA:
- 22 VA 50 Hz cos phi 0.9 (at 20 °C)
- 22 VA 60 Hz cos phi 0.9 (at 20 °C)
- Heat dissipation: 3…8 W for control circuit
- Operating time:
- 20...50 ms on closing
- 6...20 ms on opening
- Maximum operating rate: 1200 cyc/h 55 °C
- Connections - terminals:
- Power circuit: screw clamp terminals 1 10…120 mm² - cable stiffness: flexible without cable end
- Power circuit: screw clamp terminals 1 10…120 mm² - cable stiffness: flexible with cable end
- Power circuit: screw clamp terminals 1 10…120 mm² - cable stiffness: solid without cable end
- Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible without cable end
- Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end
- Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end
- Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
- Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: solid without cable end
- Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end
- Power circuit: screw clamp terminals 2 10…120 mm² - cable stiffness: solid without cable end
- Tightening torque:
- Power circuit: 12 N.m
- Control circuit: 1.2 N.m
- Auxiliary contact composition: 1 NO + 1 NC
- Minimum switching voltage: 17 V for control circuit
- Minimum switching current: 5 mA for control circuit
- Insulation resistance: > 10 MOhm for control circuit
- Non-overlap time:
- 1.5 ms on energisation guaranteed between NC and NO contact
- 1.5 ms on de-energisation guaranteed between NC and NO contact
- Mounting support: Plate, DIN rail